Fan light common failure repair method

First, the fan turn light does not light

1, check whether the bulb is screwed tight.

2, turn off the power, fan lights with remote control, after excluding the above problems, should remove the receiver, the standard black line connected to the power supply fire line, blue

Line connected to the power supply zero line, and then open the power test, if the fan and lights are normal, the receiver failure, for a good set of receivers can be.

3, turn off the power, check whether the lamp head shrapnel poor contact, with a screwdriver toggle

4, replace the bulb to test whether the bulb burned out.

5, no remote control group of fans or remove the receiver after the fan or fan turn lights do not light the fan, after ruling out the above 123 points, you should check the

9P terminal or male and female terminals are not in good contact, if loose, will be returned to its place.

Second, the light fan shaking

1, check the installation of bad conditions, the ceiling needs to be cement ceiling or load-bearing {>} 25 kg and thickness {>} 10 cm of wood ceiling; gypsum ceiling

Plaster ceiling and bearing less than 25 kg of wood ceiling does not allow the direct installation of fan lights, need to make another hanger to strengthen the processing.

2、Check whether the leaf frame and motor are locked, leaf frame and blade are locked.

3、Check whether the installation of the hanger is correct and stable.

Check whether the joint screws of the boom connecting to the mainframe are locked. There are two screws here, both need to be locked.

4,

5, if there is still a problem after the above check, then check whether the leaf blade frame is deformed due to impact in the installation process.

Third,Lights on the fan does not turn

1, turn off the power, check whether the motor wiring is correct, such as wall control (light fan sub-control), should check whether the light fan switch is accessed correctly.

2, equipped with a remote control group of ceiling fan lights, remove the receiver, the motor will be brown and black wire and power supply line, blue line and power supply zero line, and then turn on the power supply, if normal, then for the receiver

Receiver failure, replace a good set of receiver can be.

3, exclude the above possibilities, such as failure still exists, it is very likely that the motor fuse blown, should be returned to the factory for repair (return to the factory try to use the original packaging, in order to protect the electricity).

)

4, check whether the 9P terminal in the switch box is loose or not in place, if so, will be attributed to can.

Fourth, the remote control class failure

Turn off the power, check the appearance of the receiver whether there is deformation, if so, the receiver is burned out, burned out particularly serious, can not be returned to repair.

1.

2, remove the receiver will light fan directly connected to the power supply, such as the light fan is normal, the receiver failure, should be returned to the factory for repair.

3.

Check whether the wiring of the receiver is correct and firm.

Updated on July 21, 2024